020021 | Alarm Cable 2×0.22 mm² ∙ PVC ∙ Al/PET Shielding + Cu Drain ∙ 100 m

Brand: Elan
Product Code: EL00020021

ELAN 2 × 0.22 mm² alarm and control cable for fixed signal, command and communication lines.

Its flexible stranded construction supports practical installation in conduits and cable routes. Overall shielding helps reduce electromagnetic interference on low-level signal lines.

  • Conductor configuration: 2 × 0.22 mm²
  • Conductor construction: flexible bare copper, 7 × Ø 0.170 mm
  • Jacket: semi-pressed white RZ-type flame-retardant PVC
  • Shielding: overall Al/PET foil, 100% coverage
  • Drain wire: tinned copper, Ø 0.5 mm
  • Packaging length: 100 m

Outer diameter (Ø): 3.20 ± 0.20 mm


General
  • Cable category: Alarm / control cable
  • Cable type: Shielded PVC cable
  • Conductor configuration: 2 × 0.22 mm²
Performance & Technical Characteristics
  • Conductor resistance: Max. 110 Ω/km at 20 °C
  • Insulation resistance: Min. 200 MΩ/km at 20 °C
Electrical & Power
  • Operating voltage: ≤100 V
  • Test voltage: 1,000 V / 1 min / 50 Hz
  • Cable voltage rating: U₀=400 V according to CEI 36762 C-4
Construction & Mechanical
  • Colour: White jacket · white/red cores
  • Conductor material: Bare Copper
  • Conductor cross-section: 0.22 mm² per conductor
  • Conductor construction: 7 × Ø 0.170 mm, flexible stranded
  • Conductor insulation: R2-type PVC, thickness >0.20 mm · insulated conductor Ø 1.00 mm
  • Shielding: Overall Al/PET foil, 100% coverage
  • Drain wire: Tinned copper, Ø 0.5 mm
  • Jacket: Semi-pressed white RZ-type PVC, flame-retardant, with ripcord
  • Jacket thickness: >0.5 mm
  • Outer diameter: 3.20 ± 0.20 mm
  • Weight per unit length: 15.33 kg/km ±5%
  • Minimum bend radius: 12 × outer diameter, 38.4 mm
Installation & Compatibility
  • Installation type: Indoor fixed installation in cable trays, ducts or conduits
  • Cabling requirements: Routing with 450/750 V and 0.6/1 kV power cables according to CEI UNEL 36762 for C-4 classification
Environment & Protection
  • Operating temperature: -15 °C to +80 °C
  • Installation environment: Indoor
Standards & Compliance
  • Applicable standards: CEI 20-11 · CEI 20-29 · CEI 20-20 · CEI 20-22 III / IEC 60332-3 · CEI 36762 · EN 50575
  • CPR class: Eca
  • CPR harmonised standard: EN 50575:2014+A1:2016
  • CE compliance: Yes
  • RoHS compliance: Yes
  • Declaration of Performance: A/001/2020
Packaging & Contents
  • Packaging length: 100 m

Shielded 2 × 0.22 mm² alarm and control cable for fixed indoor signal, command and communication lines. Its construction combines two flexible stranded bare-copper conductors, overall Al/PET shielding, a tinned-copper drain conductor and a semi-pressed white RZ-type PVC outer jacket.

Product code 020021 is the 100 m packaging version in the ELAN Alarm Cables Shielded (U₀=400 V) category. The CEI 36762 C-4 classification concerns installation with power cables according to CEI UNEL 36762, while the operating-voltage rating of the 0.22 mm² conductors remains ≤100 V. The cable is intended for indoor installation in cable trays, ducts, conduits or other protected routes.

Product Identity
  • Manufacturer: ELAN s.r.l.
  • Product code: 020021.
  • Product type: shielded PVC alarm / control cable.
  • Configuration: 2 × 0.22 mm², 100 m packaging.
  • Marking: ELAN A.F. CEI 20/22 III - CEI 36762 C-4 (U₀=400 V).
  • Installation environment: indoor, fixed installation.
  • Product code 020021 corresponds to the 2 × 0.22 mm² configuration with 3.20 mm nominal outer diameter and 15.33 kg/km weight.
Conductors and insulation
  • Signal conductors: 2 × 0.22 mm² bare copper.
  • Construction of each conductor: 7 × Ø 0.170 mm, flexible stranded.
  • Conductor insulation: R2-type PVC, thickness above 0.20 mm, for the 0.22 mm² signal conductors.
  • Insulated-conductor diameter: Ø 1.00 mm.
  • Core colours for 020021: white and red.
  • Conductors assembled with polyester tape.
  • The 0.22 mm² cross-section applies to each individual signal conductor.
Shielding and jacket
  • Overall shielding with coupled aluminium/polyester (Al/PET) foil, 100% coverage.
  • Shield construction: 9/12 μm aluminium/polyester foil.
  • Drain conductor: tinned copper, Ø 0.5 mm.
  • 12 μm polyester tape placed over the assembled conductors.
  • Outer jacket: semi-pressed white RZ-type PVC, flame-retardant.
  • The jacket incorporates a ripcord.
  • Outer-jacket thickness: above 0.5 mm.
  • Jacket flame behaviour is referenced to CEI 20-22 III / IEC 60332-3.
Electrical characteristics
  • Operating voltage for 0.22 mm² conductors: ≤100 V.
  • Test voltage: 1,000 V for 1 min at 50 Hz.
  • Maximum conductor resistance at 20 °C: 110 Ω/km.
  • Minimum insulation resistance at 20 °C: 200 MΩ/km.
  • Installation classification: C-4 (U₀=400 V) according to CEI 36762.
  • Routing with 450/750 V and 0.6/1 kV power cables is permitted according to CEI UNEL 36762.
  • The U₀=400 V value belongs to the C-4 installation classification and remains distinct from the operating-voltage rating of the 0.22 mm² conductors.
Mechanical and environmental characteristics
  • Outer diameter: Ø 3.20 ± 0.20 mm.
  • Weight per unit length: 15.33 kg/km ±5%.
  • Operating temperature: -15 °C to +80 °C.
  • Minimum installation bend radius: 12 × outer diameter, corresponding to 38.4 mm at nominal diameter.
  • Intended for fixed indoor installation in cable trays, ducts, conduits or other protected routes.
  • The nominal diameter and weight values apply specifically to the 2 × 0.22 mm² configuration represented by product code 020021.
Standards and compliance
  • Applicable references: CEI 20-11, CEI 20-29, CEI 20-20, CEI 20-22 III / IEC 60332-3, CEI 36762 and EN 50575.
  • CPR reaction-to-fire class: Eca.
  • Declaration of Performance: A/001/2020.
  • CPR intended use: control and communication cable for general applications in construction works subject to reaction-to-fire requirements.
  • Assessment and Verification of Constancy of Performance system: AVCP 3.
  • Notified body: LAPI SPA, No. 0987.
  • Dangerous substances declared in the DoP: none.
  • CE marked and RoHS compliant.
  • The shielded alarm-cable category is documented as flame-retardant and suitable for indoor installation with power cables under the cited CEI conditions.
  • DoP A/001/2020 identifies the product through entries 02002(1), 02002(5) and 02002(9).
Packaging
  • Packaging length for product code 020021: 100 m.