020041 | Alarm Cable 4×0.22 mm² ∙ PVC ∙ Al/PET Shielding + Cu Drain ∙ 100 m
Brand: ElanProduct Code: EL00020041
ELAN 4 × 0.22 mm² alarm and control cable for fixed signal, command and communication lines.
Its flexible stranded construction supports practical installation in conduits and cable routes. Overall shielding helps reduce electromagnetic interference on low-level signal lines.
- Conductor configuration: 4 × 0.22 mm²
- Conductor construction: flexible bare copper, 7 × Ø 0.170 mm
- Jacket: semi-pressed white RZ-type flame-retardant PVC
- Shielding: overall Al/PET foil, 100% coverage
- Drain wire: tinned copper, Ø 0.5 mm
- Packaging length: 100 m
Outer diameter (Ø): 4.00 ± 0.20 mm
- Cable category: Alarm / control cable
- Cable type: Shielded PVC cable
- Conductor configuration: 4 × 0.22 mm²
- Conductor resistance: Max. 110 Ω/km at 20 °C
- Insulation resistance: Min. 200 MΩ/km at 20 °C
- Operating voltage: ≤100 V
- Test voltage: 1,000 V at 50 Hz
- Cable voltage rating: CEI 36762 C-4, U₀ = 400 V
- Colour: White jacket · white, red, yellow and green cores
- Conductor material: Bare Copper
- Conductor cross-section: 0.22 mm² per conductor
- Conductor construction: 7 × Ø 0.170 mm, flexible stranded
- Conductor insulation: PVC, thickness >0.20 mm · insulated conductor Ø 1.00 mm
- Shielding: Overall Al/PET foil, 100% coverage
- Drain wire: Tinned copper, Ø 0.5 mm
- Jacket: Semi-pressed white RZ-type PVC, flame-retardant
- Jacket thickness: >0.5 mm
- Outer diameter: 4.00 ± 0.20 mm
- Weight per unit length: 22.48 kg/km ±5%
- Minimum bend radius: 12 × outer diameter
- Installation type: Indoor fixed installation
- Cabling requirements: Routing with 450/750 V and 0.6/1 kV power cables according to CEI UNEL 36762
- Operating temperature: −15 °C to +80 °C
- Installation environment: Indoor
- Applicable standards: CEI 20-11 · CEI 20-29 · CEI 20-20 · CEI 20-22 III · IEC 60332 · CEI 36762 · EN 50575
- CPR class: Eca
- CPR harmonised standard: EN 50575:2014+A1:2016
- Declaration of Performance: A/002/2020
- Packaging length: 100 m
Shielded four-core 0.22 mm² alarm and control cable for fixed indoor signal and communication lines. Its construction combines flexible stranded Bare Copper conductors, 100% coverage overall Al/PET shielding, a tinned-copper drain conductor and a white RZ-type PVC outer jacket.
The CEI 36762 C-4 (U₀=400 V) classification permits combined routing with power cables in accordance with CEI UNEL 36762, while its documented construction, electrical values and CPR Eca class support professional alarm and control installations where overall metallic shielding is required.
Product Identity- Manufacturer: ELAN s.r.l.
- Manufacturer code: 020041.
- Product type: Shielded alarm and control cable for indoor installation.
- Family: Alarm Cable Shielded (U₀=400 V), PVC.
- Configuration: 4 × 0.22 mm², 100 m packaging.
- Conductors: 4 × 0.22 mm² Bare Copper, flexible stranded construction.
- Construction of each conductor: 7 wires, each Ø 0.170 mm.
- Conductor insulation: PVC, thickness greater than 0.20 mm.
- Insulated conductor diameter: Ø 1.00 mm.
- Colours of the four conductors: white, red, yellow and green.
- Assembly: helically laid insulated conductors with polyester foil.
- Overall shielding: aluminium/polyester Al/PET foil with 100% coverage of the cable assembly.
- The shield is common to the complete group of four insulated conductors rather than individual shielding around each conductor.
- Drain conductor: tinned copper, Ø 0.5 mm, for termination of the overall shield.
- Outer jacket: semi-pressed white RZ-type PVC, thickness greater than 0.5 mm.
- The jacket is flame-retardant and incorporates a ripcord to facilitate jacket removal during termination.
- Operating voltage for the 0.22 mm² conductors: ≤100 V.
- Test voltage: 1,000 V at 50 Hz.
- Maximum conductor electrical resistance at 20 °C: 110 Ω/km.
- Minimum insulation resistance at 20 °C: 200 MΩ/km.
- Cable classification: CEI 36762 C-4 (U₀=400 V).
- The C-4 classification relates to installation according to CEI UNEL 36762 requirements and does not change the documented operating voltage of the individual conductors.
- The family cable marking includes CEI 20/22 III and CEI 36762 C-4 (U₀=400 V), allowing the construction category to be identified on the cable.
- Outer diameter: Ø 4.00 ± 0.20 mm.
- Weight per unit length: 22.48 kg/km ±5%.
- Minimum installation bend radius: 12 × outer diameter.
- Operating temperature: -15 °C to +80 °C.
- Designed for fixed indoor installation in ducts, conduits or other suitable protected routing systems.
- It may be routed with 450/750 V and 0.6/1 kV power cables when installation follows CEI UNEL 36762 requirements for C-4 cables.
- The overall Al/PET shield and drain conductor provide continuity and practical termination of the shielding on signal lines.
- Standards stated for the family: CEI 20-11, CEI 20-29, CEI 20-20, CEI 20-22 III, IEC 60332 and CEI 36762.
- Declaration of Performance: A/002/2020 for Alarm PVC cables of the applicable configuration.
- Harmonised CPR standard: EN 50575:2014+A1:2016.
- Reaction-to-fire class: Eca.
- Assessment and verification of constancy of performance system: AVCP 3.
- Notified body: 0987 – LAPI SPA.
- Dangerous substances declared in the DoP: none.
- The DoP is issued under Regulation (EU) No. 305/2011 for construction products and declares the reaction-to-fire performance for the applicable family code.
- Declared CPR use: control and communication cable for general application in construction works subject to reaction-to-fire requirements.
- Code 020041: packaging length 100 m, matching the 100 m variant in the current ELAN catalogue.
- The same 02004 family is also supplied under other packaging codes for 200 m and 500 m; this product entry refers exclusively to code 020041 with 100 m packaging.