098233 | ELANDATA CAT6 U/UTP 4x2x23AWG Network Cable ∙ LSZH ∙ 305 m
Product Code: EL00098233
098233 | ELANDATA CAT6 U/UTP 4x2x23AWG Network Cable ∙ LSZH ∙ 305 m
Brand: ElanProduct Code: EL00098233
CAT6 network cable for fixed LAN and structured-cabling installations.
Its construction supports reliable data transmission and tidy installation in the intended environment.
- Network category: CAT6
- Conductor configuration: 4 × 2 × 23AWG
- Conductor construction: 100% bare copper Ø 0.57 mm
- Shielding: U/UTP
- Jacket: grey LSZH with internal pair separator
- Packaging length: 305 m
Outer diameter (Ø): 6.00 ± 0.20 mm
General
- Cable category: Network / LAN cable
- Cable type: U/UTP
- Network category: CAT6
- Conductor configuration: 4×2×23AWG
Performance & Technical Characteristics
- Characteristic impedance: 100 ±15 Ω (1–100 MHz)
- Maximum capacitance: 56 pF/m
- Propagation velocity: 0.68 c at 100 MHz
Construction & Mechanical
- Weight: 40 kg/km
- Conductor material: Bare Copper
- Bare conductor diameter: 0.57 mm
- Conductor insulation: HDPE, thickness >0.20 mm
- Jacket: LSZH, M1 type according to CEI 20-11
- Outer diameter: 6.00 ±0.20 mm
- Minimum bend radius: 10 × outer diameter
Environment & Protection
- Operating temperature: -20 °C to +60 °C
Standards & Compliance
- CPR class: Eca
- CPR harmonised standard: EN 50575:2014+A1:2016
Packaging & Contents
- Packaging length: 305 m
Construction
- Product range: ELANDATA
- Category: CAT6
- Type: U/UTP
- Configuration: 4x2x23AWG, 4 twisted pairs / 8 conductors
- Conductor material: Bare Copper
- Bare conductor diameter: 0.57 mm
- Conductor insulation: HDPE, thickness >0.20 mm
- Separator: Internal CAT6 pair separator
- Pair colours: White/Blue–Blue, White/Orange–Orange, White/Green–Green, White/Brown–Brown
Jacket and Mechanical Characteristics
- Jacket: Flexible LSZH compound, M1 type according to CEI 20-11
- Jacket properties: Low smoke, zero halogen and flame-retardant behaviour
- Outer diameter: 6.00 ±0.20 mm
- Weight: 40 kg/km
- Operating temperature: -20 °C to +60 °C
- Minimum bend radius: 10 × outer diameter
- Packaging length: 305 m
Electrical and Transmission Characteristics
- Characteristic impedance, 1–100 MHz: 100 ±15 Ω
- Maximum resistance unbalance: 2%
- Maximum capacitance: 56 pF/m
- Maximum capacitance unbalance: 3.3 pF/m
- Propagation velocity at 100 MHz: 0.68 c
- 1 MHz: attenuation 1.9 dB/100 m, NEXT 75 dB, RL ≥20.0 dB
- 100 MHz: attenuation 19.3 dB/100 m, NEXT 53 dB, RL ≥20.1 dB
- 250 MHz: attenuation 32.8 dB/100 m, NEXT 38 dB, RL ≥17.3 dB
Standards, Installation and CPR
- Standards: CEI 20-11, CEI 20-29, CEI 20-20, CEI 20-22/III, IEC 60332, IEC 61156-5 and ISO/IEC 11801
- Marking: CEI 36762 C-4, Uo = 400 V
- Co-installation: Permitted with 450/750 V and 0.6/1 kV power cables according to CEI UNEL 36762
- Declaration of Performance: DoP 14/2024
- CPR: Regulation (EU) No. 305/2011
- Harmonised standard: EN 50575:2014+A1:2016
- Reaction-to-fire class: Eca
- Assessment system: AVCP 3
- Notified body: LAPI SPA, No. 0987
- Dangerous substances: None declared
CAT6 Channel Reference Test
- Fluke Networks DTX-1800 test performed on 19/04/2026
- Test limit: TIA Cat 6 Channel
- Overall result: PASS
- Tested channel length: 262 ft / approximately 79.9 m
- Wire Map: PASS, T568B
- NVP: 69%
- Propagation Delay: 474 ns, limit 555 ns
- Delay Skew: 21 ns, limit 50 ns
- Resistance: 20.8 Ω
- Insertion Loss Margin: 6.9 dB at 250 MHz
- NEXT Headroom: 5.3 dB
- Results relate to the specific tested channel and are not a general certification of every installation.